Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Crit Care ; 25(1): 431, 2021 12 16.
Article in English | MEDLINE | ID: covidwho-1854857

ABSTRACT

BACKGROUND: We hypothesized that as CARDS may present different pathophysiological features than classic ARDS, the application of high levels of end-expiratory pressure is questionable. Our first aim was to investigate the effects of 5-15 cmH2O of PEEP on partitioned respiratory mechanics, gas exchange and dead space; secondly, we investigated whether respiratory system compliance and severity of hypoxemia could affect the response to PEEP on partitioned respiratory mechanics, gas exchange and dead space, dividing the population according to the median value of respiratory system compliance and oxygenation. Thirdly, we explored the effects of an additional PEEP selected according to the Empirical PEEP-FiO2 table of the EPVent-2 study on partitioned respiratory mechanics and gas exchange in a subgroup of patients. METHODS: Sixty-one paralyzed mechanically ventilated patients with a confirmed diagnosis of SARS-CoV-2 were enrolled (age 60 [54-67] years, PaO2/FiO2 113 [79-158] mmHg and PEEP 10 [10-10] cmH2O). Keeping constant tidal volume, respiratory rate and oxygen fraction, two PEEP levels (5 and 15 cmH2O) were selected. In a subgroup of patients an additional PEEP level was applied according to an Empirical PEEP-FiO2 table (empirical PEEP). At each PEEP level gas exchange, partitioned lung mechanics and hemodynamic were collected. RESULTS: At 15 cmH2O of PEEP the lung elastance, lung stress and mechanical power were higher compared to 5 cmH2O. The PaO2/FiO2, arterial carbon dioxide and ventilatory ratio increased at 15 cmH2O of PEEP. The arterial-venous oxygen difference and central venous saturation were higher at 15 cmH2O of PEEP. Both the mechanics and gas exchange variables significantly increased although with high heterogeneity. By increasing the PEEP from 5 to 15 cmH2O, the changes in partitioned respiratory mechanics and mechanical power were not related to hypoxemia or respiratory compliance. The empirical PEEP was 18 ± 1 cmH2O. The empirical PEEP significantly increased the PaO2/FiO2 but also driving pressure, lung elastance, lung stress and mechanical power compared to 15 cmH2O of PEEP. CONCLUSIONS: In COVID-19 ARDS during the early phase the effects of raising PEEP are highly variable and cannot easily be predicted by respiratory system characteristics, because of the heterogeneity of the disease.


Subject(s)
COVID-19/therapy , Positive-Pressure Respiration , Respiratory Distress Syndrome/therapy , Ventilator-Induced Lung Injury , COVID-19/diagnosis , Critical Care , Humans , Hypoxia , Middle Aged , Oxygen/therapeutic use , SARS-CoV-2 , Ventilator-Induced Lung Injury/diagnostic imaging
2.
J Clin Med ; 10(21)2021 Oct 21.
Article in English | MEDLINE | ID: covidwho-1480817

ABSTRACT

BACKGROUND: Systemic corticosteroids are associated with reduced mortality in COVID-19-related acute respiratory failure; however, the type and dose has not yet been established. OBJECTIVES: To compare the outcomes of dexamethasone vs. methylprednisolone, along with the effects of rescue, short-term, high-dose boluses of corticosteroids. METHODS: Before/after and case/control retrospective analysis of consecutive critically ill COVID-19 subjects. Subjects were initially given dexamethasone; however, after review of the local protocol, methylprednisolone was suggested. A three-day course of 1000 mg/day of methylprednisolone was administered in the case of refractory hypoxemia within the first 10 days of treatment. Propensity score-adjusted comparisons were performed. RESULTS: A total of 81 consecutive subjects were included (85% males, 60 ± 10 years, SAPS II 27 ± 7, SOFA 4 [IQR 3, 6] points) and 51 of these subjects (62.9%) received dexamethasone and 29 (35.8%) had methylprednisolone. The groups were well matched for age, comorbidities, and severity at admission. No differences were found in the duration of ICU stay, hospital mortality, or infectious complications between the groups. A total of 22 subjects (27.2%) received a rescue bolus; these subjects had a significantly lower oxygenation, a higher driving pressure, and an increased ventilatory ratio during the first ten days. Short-term/high-dose boluses were associated with higher hospital mortality, longer mechanical ventilation and ICU and hospital stay, and more infectious complications. A subgroup of subjects who received the boluses had significantly improved oxygenation and lower hospital mortality. CONCLUSIONS: We were unable to find any difference between dexamethasone or methylprednisolone on the explored outcomes; high-dose boluses of corticosteroids were associated with a worse outcome. However, a subgroup of subjects was identified in whom the high-dose boluses seemed beneficial.

3.
Nutrition ; 91-92: 111449, 2021.
Article in English | MEDLINE | ID: covidwho-1440280

ABSTRACT

OBJECTIVES: Severe forms of the novel coronavirus-19 (COVID-19) are associated with systemic inflammation and hypercatabolism. The aims of this study were to compare the time course of the size and quality of both rectus femoris and diaphragm muscles between critically ill, COVID-19 survivors and non-survivors and to explore the correlation between the change in muscles size and quality with the amount of nutritional support delivered and the cumulative fluid balance. METHODS: This was a prospective observational study in the general intensive care unit (ICU) of a tertiary care hospital for COVID-19. The right rectus femoris cross-sectional area and the right diaphragm thickness, as well as their echo densities were assessed within 24 h from ICU admission and on day 7. We recorded anthropometric and biochemical data, respiratory mechanics and gas exchange, daily fluid balance, and the number of calories and proteins administered. RESULTS: Twenty-eight patients were analyzed (65 ± 10 y of age; 80% men, body mass index 30 ± 7.8 kg/m2). Rectus femoris and diaphragm sizes were significantly reduced at day 7 (median = -26.1 [interquartile ratio [IQR], = -37.8 to -15.2] and -29.2% [-37.8% to -19.6%], respectively) and this reduction was significantly higher in non-survivors. Both rectus femoris and diaphragm echo density were significantly increased at day 7, with a significantly higher increase in non-survivors. The change in both rectus femoris and diaphragm size at day 7 was related to the cumulative protein deficit (R = 0.664, P < 0.001 and R = 0.640, P < 0.001, respectively), whereas the change in rectus femoris and diaphragm echo density was related to the cumulative fluid balance (R = 0.734, P < 0.001 and R = 0.646, P < 0.001, respectively). CONCLUSIONS: Early changes in muscle size and quality seem related to the outcome of critically ill COVID-19 patients, and to be influenced by nutritional and fluid management strategies.


Subject(s)
COVID-19 , Respiratory Distress Syndrome , Critical Illness , Female , Humans , Male , Quadriceps Muscle/diagnostic imaging , Respiratory Distress Syndrome/diagnostic imaging , SARS-CoV-2 , Ultrasonography
5.
Intensive Care Med ; 46(12): 2187-2196, 2020 12.
Article in English | MEDLINE | ID: covidwho-886981

ABSTRACT

PURPOSE: To investigate whether COVID-19-ARDS differs from all-cause ARDS. METHODS: Thirty-two consecutive, mechanically ventilated COVID-19-ARDS patients were compared to two historical ARDS sub-populations 1:1 matched for PaO2/FiO2 or for compliance of the respiratory system. Gas exchange, hemodynamics and respiratory mechanics were recorded at 5 and 15 cmH2O PEEP. CT scan variables were measured at 5 cmH2O PEEP. RESULTS: Anthropometric characteristics were similar in COVID-19-ARDS, PaO2/FiO2-matched-ARDS and Compliance-matched-ARDS. The PaO2/FiO2-matched-ARDS and COVID-19-ARDS populations (both with PaO2/FiO2 106 ± 59 mmHg) had different respiratory system compliances (Crs) (39 ± 11 vs 49.9 ± 15.4 ml/cmH2O, p = 0.03). The Compliance-matched-ARDS and COVID-19-ARDS had similar Crs (50.1 ± 15.7 and 49.9 ± 15.4 ml/cmH2O, respectively) but significantly lower PaO2/FiO2 for the same Crs (160 ± 62 vs 106.5 ± 59.6 mmHg, p < 0.001). The three populations had similar lung weights but COVID-19-ARDS had significantly higher lung gas volume (PaO2/FiO2-matched-ARDS 930 ± 644 ml, COVID-19-ARDS 1670 ± 791 ml and Compliance-matched-ARDS 1301 ± 627 ml, p < 0.05). The venous admixture was significantly related to the non-aerated tissue in PaO2/FiO2-matched-ARDS and Compliance-matched-ARDS (p < 0.001) but unrelated in COVID-19-ARDS (p = 0.75), suggesting that hypoxemia was not only due to the extent of non-aerated tissue. Increasing PEEP from 5 to 15 cmH2O improved oxygenation in all groups. However, while lung mechanics and dead space improved in PaO2/FiO2-matched-ARDS, suggesting recruitment as primary mechanism, they remained unmodified or worsened in COVID-19-ARDS and Compliance-matched-ARDS, suggesting lower recruitment potential and/or blood flow redistribution. CONCLUSIONS: COVID-19-ARDS is a subset of ARDS characterized overall by higher compliance and lung gas volume for a given PaO2/FiO2, at least when considered within the timeframe of our study.


Subject(s)
COVID-19/physiopathology , Respiratory Distress Syndrome/physiopathology , Adult , Aged , Blood Gas Analysis/methods , COVID-19/therapy , Cohort Studies , Female , Humans , Intensive Care Units/organization & administration , Intensive Care Units/statistics & numerical data , Italy , Length of Stay/statistics & numerical data , Lung Compliance/physiology , Male , Middle Aged , Prospective Studies , Pulmonary Gas Exchange/physiology , Respiratory Distress Syndrome/therapy , Simplified Acute Physiology Score , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL